![Sony GY-2120WD Maintenance Manual Download Page 300](http://html.mh-extra.com/html/sony/gy-2120wd/gy-2120wd_maintenance-manual_410991300.webp)
6-76
GY-2120WD/WS
6-2. Description of Commands
#.
: H_DPR_REG0_8 (C1 correction control)
$/
: H_DPR_REG0_F (option mode DATA resistor)
$-
: H_DPR_REG0_E (option mode ADDRESS resistor)
$=
: H_DPR_REG0_D ((not used))
$[
: H_DPR_REG0_C (C1 random error (Dch)) Hex
#;
: H_DPR_REG0_B (C1 random error (Cch)) reference
$]
: H_DPR_REG1_3 (erasure off/C2 dec control)
$\
: H_DPR_REG1_2 (C2 error correction ability (e
+
n))
$;
: H_DPR_REG1_1 (C2 error correction ability (e))
$'
: H_DPR_REG1_0 (C2 error correction ability (n))
C2 Error correction setting value
Normal value
A0
$,
: H_DPR_REG1_7 (C1 burst error (Cch)) Hex
$.
: H_DPR_REG1_6 (C1 burst error (Bch)) Hex
%/
: H_DPR_REG1_5 (C1 burst error (Ach)) Hex
Number of blocks which could be read correctly after C1 error correction.
When all the data in the block could be read, then;
D0 (Hex) = 208 blocks.
This indicates that the greater the number, the better is the data state of each channel.
(No. of blocks which could not be corrected) = 208
_
(C1 burst error of each channel)
C2 error correction is carried out for data of blocks which could not be corrected.
%-
: H_DPR_REG1_4 (REC_ENABLE/SAT ON/OFF control)
%=
: H_DPR_REG1_B (Mechanism adjustment signal generation control)
%[
: H_DPR_REG1_A (Mechanism adjustment REC ENABLE control)
%]
: H_DPR_REG1_9 (FM parity err)
b1 : parity error
1 : parity error exist
0 : no error
Normal value
0
Normal value
FC or FD