![Sony GY-2120WD Maintenance Manual Download Page 408](http://html.mh-extra.com/html/sony/gy-2120wd/gy-2120wd_maintenance-manual_410991408.webp)
6-184
GY-2120WD/WS
6-3-8. Countermeasures for DIAG Error Codes and List of Maintenance Parts
Error Code
Processing
Replacement Parts List
0120
SCSI-SYS CPU com. check error
MA-83 or GY-2120
0130
LCD Display check error
DSP-78, MA-83 or GY-2120
0140
LED Display check error
DSP-78, MA-83 or GY-2120
0150
SCSI CPU ROM check error
MA-83 or GY-2120
0160
SCSI CPU RAM check error
MA-83 or GY-2120
0220
SYS CPU ROM check error
MA-83 or GY-2120
0230
SYS CPU RAM check error
MA-83 or GY-2120
0320
loopback-3 check error
MA-83 or GY-2120
0330
loopback-2 check error
EQ-66 or GY-2120
0340
loopback-1 check error
EQ-66 or GY-2120
0410
bank memory check error
MEM-83, MA-83 or GY-2120
0520
IF CPU ROM check error
IF-682 or GY-2120
0530
IF CPU RAM check error
IF-682 or GY-2120
1000
Requested tape not instert
-Instert the tape-
1001
Servo unlock in the DIAG
-Retry the same DIAG or Replace the DIAG tape-
1002
Cassette rec inhibit sw ON
-rec inhibit sw OFF-
1003
RF error rate check NG
-readjust, RP or GY-2120
*RP...Upper Drum Assy, EQ-66, SW Regulator
1020
PF PB Level adjust failed
-Readjust, RP or GY-2120
1030
PF PB PLL adjust failed
-Readjust, RP or GY-2120
1040
PF PB Equalizer adjust failed
-Readjust, RP or GY-2120
1050
PF REC current adjust failed
-Readjust, RP or GY-2120
2020
S Reel FG Duty adjust failed
-Readjust, DR-327, MS-54 or GY-2120
2030
T Reel FG Duty adjust failed
-Readjust, DR-327, MS-54 or GY-2120
2040
Capstan FG Duty adjust failed
-Readjust, DR-327, MS-54, MA-83 or GY-2120
2050
S Reel Offset/Friction adj. failed
-Readjust, DR-327, MS-54 or GY-2120
2060
T Reel Offset/Friction adj. failed
-Readjust, DR-327, MS-54 or GY-2120
2070
S Reel Torque adjust failed
-Readjust, DR-327, MS-54 or GY-2120
2080
T Reel Torque adjust failed
-Readjust, DR-327, MS-54 or GY-2120
2090
S/T Tension Offset adj. failed
-Readjust, DR-327, MS-54 or GY-2120
2280
S Reel FG/Motor check error
-Readjust, DR-327, MS-54 or GY-2120
2281
T Reel FG/Motor check error
-Readjust, DR-327, MS-54 or GY-2120
2282
Capstan FG/Motor check error
-Readjust, DR-327, MS-54 or GY-2120
2283
S Reel Offset/Friction check error
-Readjust, DR-327, MS-54 or GY-2120
2284
T Reel Offset/Friction check error
-Readjust, DR-327, MS-54 or GY-2120
2285
S Reel Torque check error
-Readjust, DR-327, MS-54 or GY-2120
2286
T Reel Torque check error
-Readjust, DR-327, MS-54 or GY-2120
9000
Drum Hours meter (replace) reset failed
MS-54
9010
Drum Hours meter (cleaning) reset failed
MS-54
9020
Tape run hours meter reset failed
MS-54
9040
Threading counter reset failed
MS-54
6-3. Error Processing
Summary of Contents for GY-2120WD
Page 10: ......
Page 224: ......
Page 437: ...7 3 GY 2120WD WS Index Mechanical Deck Overall Block 6 7 9 8 2 1 3 4 5 ...
Page 469: ...8 1 GY 2120WD WS 8 1 Section 8 Block Diagrams Frame Wiring ...
Page 476: ......
Page 482: ......