6-11
GY-2120WD/WS
SCSI CPU Block Check
a) 2-Port Communication Check (Self-diagnosis command No. 12)
Enter “12” as a command number and press the ENTER key.
The dual port RAM between the SCSI CPU and DRIVE CPU is automatically checked for operation.
DIAGNOSTIC=>12
-------[ 2-Port Communication Check ]-------
Start
********
OK
DIAGNOSTIC=>_
In case that the check succeeds;
Message “OK” is displayed.
In case that the check fails;
Message “ERROR!!(ERROR:xxxxxxxx WARNING:yyyyyyyy)” is displayed.
“xxxxxxxx” indicates the error code, and “yyyyyyyy” indicates the warning code.
b) LCD Check (Self-diagnosis command No. 13)
Enter “13” as a command number and press the ENTER key.
Whether the display on the LCD is normal is checked.
Check operatoin procedure
1.
Displays the character string corresponding to the entered code on the LCD for about one second.
2.
Outputs the code of the displayed character string from the LCD block.
3.
Compares the code of the entered character string with that of the character string displayed on
the LCD.
DIAGNOSTIC=>13
-------[ LCD Check ]-------
LCD Test
********
OK
DIAGNOSTIC=>_
In case that the check succeeds;
Message “OK” is displayed.
In case that the check fails;
Message “ERROR!!(STRING:xxxxxxxxxxxxxxxx)” is displayed.
“xxxxxxxxxxxxxxxx” indicates the character string displayed on the LCD.
6-2. Command Description
Summary of Contents for GY-2120WD
Page 10: ......
Page 224: ......
Page 437: ...7 3 GY 2120WD WS Index Mechanical Deck Overall Block 6 7 9 8 2 1 3 4 5 ...
Page 469: ...8 1 GY 2120WD WS 8 1 Section 8 Block Diagrams Frame Wiring ...
Page 476: ......
Page 482: ......