![Sony GY-2120WD Maintenance Manual Download Page 306](http://html.mh-extra.com/html/sony/gy-2120wd/gy-2120wd_maintenance-manual_410991306.webp)
6-82
GY-2120WD/WS
6-2. Description of Commands
HOURS
Hours Meter
Function:
Displays the hours meter and thread counter values.
The numeric value of an hours meter is displayed in units of one hour.
Operation:
Enter command.
Example:
Hours Meter
Operation Hours= 2252 Drum Run-1 Hours(res)= 64
Drum Run Hours = 697 Drum Run-2 Hours(res)= 62
Tape Run Hours = 495 Tape Run Hours (res)= 445
Thread Counter = 12955 Thread Counter (res)= 12955
Cleaning Tape = 11 Cleaning Tape (res)= 3
Invalid Clean = 2 Invalid Clean (res)= 1
Description of display:
Operation Hours
: Totally accumulated time of current conduction
*
1
Drum Run Hours
: Totally accumulated time of drum rotation
*
2
Tape Run Hours
: Totally accumulated time of tape run
Thread Counter
: Totally accumulated number of threading and unthreading counts
*
3
Drum Run-1 Hours (res) : Accumulated time of drum rotation 1
*
2
(This item is reset using an HRR command after drum replacement.)
Drum Run-2 Hours (res) : Accumulated time of drum rotation 2
*
2
(The item is automatically reset when cleaning tape is used.)
Tape Run Hours (res)
: Accumulated time of tape run
(This item can be reset using an HRR command.)
Thread Counter (res)
: Accumulated number of threading and unthreading counts
*
3
(This item can be reset using an HRR command.)
Cleaning Tape
: Total number of times the cleaning tape was used
Number of times effective cleaning operations were carried out
Cleaning Tape (res)
: Number of times the cleaning tape was used
Number of times effective cleaning operations were carried out
Reset by HRR CMD
Invalid Clean
: Total number of times the cleaning tape was used ineffectively
Number of times cleaning operations were not carried out effectively because
a cleaning tape which had reached the tape end was inserted.
Invalid Clean (res)
: Number of times the cleaning tape was used ineffectively
Number of times cleaning operations were not carried out effectively because a
cleaning tape which had reached the tape end was inserted.
Reset by HRR CMD
*
1:
Time for which this unit is energized.
*
2:
Time for which the drum rotates in the thread end state (in which the tape touches the drum).
*
3:
The cycle of one thread state is unthread end state, thread end state, then unthread end state.