6-2. Command Description
Setting Display
a) Display Baud Rate (Service setting command No. 11)
Enter “11” as a command and press the ENTER key.
The setting of baud rate is displayed as shown below. (Default: 38400 bps)
SERV => 11
Baud Rate : [4] 38400bps
SERV =>
b) Display Ignore Wide Residue Mode (Service setting command No. 13)
Enter “13” as a command and press the ENTER key.
The setting of Ignore Wide Residue Mode is displayed as shown below. (Default: ON)
When this mode is set to ON and the transmission data byte is less than the width of data bus at the wide transferring,
the target reports “Ignore Wide Residue” message.
When this mode is set to OFF, the message is not reported.
SERV => 13
Ignore Wide Residue Message Mode
: [1] Report-ON
SERV =>
c) Display BT bit Ignore Mode (Service setting command No. 14)
Enter “14” as a command and press the ENTER key.
The setting of BT bit Ignore Mode is displayed as shown below. (Default: OFF)
When this mode is set to ON, BT bit of LOCATE/READ POSITION command is ignored. Then, GY-2120 transmits
the logic block address as defined in SCSI standard regardless of the BT bit values.
When this mode is set to OFF and BT bit of LOCATE/READ POSITION command is “1”, GY-2120 responds
CHECK CONDITION.
SERV => 14
BT bit Ignore Mode
: [0] Check [OFF]
SERV =>