: READ_TIME (BCD, Time Code)
Absolute Time Code value at which LTC was read from the tape
Absolute Time Code value at which LTC was written on the tape
gg : hours
hh : minutes
ii : seconds
jj : Frames
!-
: READ_UB
UB value read from the tape
UB value written on the tape
Normal value 00000000 (Because UB is not used)
!=
: ERROR_CODE
System error code
The aa of 2xaa are recorded.
Normal value 00
![
: ABORT_CODE
Function Abort Reason Code :
—————————————————————————————————
o 00 = non_abort
: no error
o 01 = eot_reach
: EOT reached at FWD/REC
o 02 = park_bot
: park at BOT, command direction wrong
o 03 = park_eot
: park at EOT, command direction wrong
o 04 = rec_inhibit
: REC inhibit when REC message received
o 05 = search_abort
: search/preroll target point not found
(Aborted when not found after changes the search direction four times)
o 06 = incorrect_preroll : preroll length incorrect
(Should be more than 124 in front from the IN point for the “with IN” command)
o 07 = servo_unlock
: servo not locked at PLAY/REC IN timing
o 08 = not_IN_set
: IN-point is not set when “with IN” or Preroll command
Normal value 00
!]
: C_EQ_OUTPORT
SYS->SV (Free Timing)
; (b7) H : REC LOCK
; (b6) L : REC MODE
; (b5) L : EQ-LP2
; (b4) L : EQ-LP1
Write
Read
Normal value
30
F0