![Sony GY-2120WD Maintenance Manual Download Page 360](http://html.mh-extra.com/html/sony/gy-2120wd/gy-2120wd_maintenance-manual_410991360.webp)
6-136
GY-2120WD/WS
<LOG Analysis Example 1>
Method of analyzing when “Read>1124” occurs on the LCD
At the end of 2-PORT COMMAND LOG
Find ERROR!! parm [00000000 : 00000000 : 00000000] err [00000124].
No..TIME......STATUS..CMD..INFORMATION.........................................BOOT
120 009A0BEC [RCV 5] 01 ID [121905] len[ 0] eod[ 0] rty[ 0] 000BF
ERROR!! parm[00000000:00000000:00000000] err[00000124]
121 009A0BEC [FRE 5] 000BF
122 009A0C65 [FRE 6] 000BF
123 009A0CD6 [FRE 7] 000BF
124 009A0D4F [FRE 0] 000BF
125 009A1390 [FRE 1] 000BF
126 009A17A9 [FRE 2] 000BF
127 009A19A2 [FRE 3] 000BF
128 009A1A93 [FRE 4] 000BF
As err [00000124] has generated at No. 120, the LCD should become 1x24.
As CMD is 01, x is substituted by 1, and the LCD becomes 1124. As it corresponds with the actual
message on the LCD, this error is the cause.
As CMD 01 is Read and err [00000124] is Unlock Inpoint (Servo Unlock Error near IN point), Servo
Unlock occurred near ID [121905] on the tape.
6-3. Error Processing