Detailed description
2.3 Continuous -path mode
Basic logic functions: Continuouspath Mode, Exact Stop, LookAhead (B1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
37
Example 2: Effect of smoothing the path velocity and dynamic response adaptation: acceleration
mode:
BRISK
Parameter assignment
Machine data
$MC_ADAPT_PATH_DYNAMIC[0] = 3
$MC_LOOKAH_SMOOTH_FACTOR = 80%
$MA_LOOKAH_FREQUENCY[AX1] = 20 Hz
T
AX1
= 1/20 Hz = 50 ms
$MA_LOOKAH_FREQUENCY[AX2] = 20 Hz
T
AX2
= 1/20 Hz = 50 ms
$MA_LOOKAH_FREQUENCY[AX3] = 20 Hz
T
AX3
= 1/20 Hz = 50 ms
Y
W
W
W
W
W
W
Y
%
Y
Figure 2-10 Path velocity profile optimized for time without smoothing or dynamic adaptation
response
Y
W
W
W
W
W
W
Y
%
Figure 2-11 Path velocity profile with path smoothing and adaptation of dynamic response
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...