Number
Identifier: $MA_
Description
31044
ENC_IS_DIRECT2
Encoder on intermediate gear
31050
DRIVE_AX_RATIO_DENOM[n]
Denominator load gearbox
31060
DRIVE_AX_RATIO_NUMERA[n]
Numerator load gearbox
31064
DRIVE_AX_RATIO2_DENOM
Intermediate gear denominator
31066
DRIVE_AX_RATIO2_NUMERA
Intermediate gear numerator
31070
DRIVE_ENC_RATIO_DENOM[n]
Measuring gear denominator
31080
DRIVE_ENC_RATIO_NUMERA[n]
Measuring gear numerator
31090
JOG_INCR_WEIGHT
Weighting of increment for INC/handwheel
31200
SCALING_FACTOR_G70_G71
Factor for converting values when
G70
/
G71
is active
32000
MAX_AX_VELO
Maximum axis velocity
32100
AX_MOTION_DIR
Travel direction
32110
ENC_FEEDBACK_POL[n]
Sign actual value (feedback polarity)
32200
POSCTRL_GAIN [n]
Servo gain factor (Kv)
32210
POSCTRL_INTEGR_TIME
Integrator time position controller
32220
POSCTRL_INTEGR_ENABLE
Activation of integral component of position controller
32250
RATED_OUTVAL[n]
Rated output voltage
32260
RATED_VELO[n]
Rated motor speed
32450
BACKLASH[n]
Backlash
32500
FRICT_COMP_ENABLE
Friction compensation active
32610
VELO_FFW_WEIGHT
Feedforward control factor for speed feedforward
control
32620
FFW_MODE
Feedforward control mode
32630
FFW_ACTIVATION_MODE
Activate feedforward control from program
32650
AX_INERTIA
Moment of inertia for torque feedforward control
32711
CEC_SCALING_SYSTEM_METRIC
System of measurement of sag compensation
32800
EQUIV_CURRCTRL_TIME [n]
Equivalent time constant current control loop for
feedforward control
32810
EQUIV_SPEEDCTRL_TIME [n]
Equivalent time constant speed control loop for
feedforward control
32900
DYN_MATCH_ENABLE
Dynamics matching
32910
DYN_MATCH_TIME [n]
Time constant for dynamic response adaptation
32930
POSCTRL_OUT_FILTER_ENABLE
Activation of low-pass filter at position controller
output
32940
POSCTRL_OUT_FILTER_TIME
Time constant of low-pass filter at position controller
output
32950
POSCTRL_DAMPING
Factor for additional damping of position control loop
32960
POSCTRL_ZERO_ZONE[n]
Dead zone position controller
33000
FIPO_TYPE
Fine interpolator type
34320
ENC_INVERS[n]
Length measuring system is inverse
35100
SPIND_VELO_LIMIT
Maximum spindle speed
36200
AX_VELO_LIMIT [n]
Threshold value for velocity monitoring
36210
CTRLOUT_LIMIT[n]
Maximum speed setpoint
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...