Detailed Description
2.9 Mode group, channel, program operation, reset response (K1)
Basic logic functions: NC/PLC interface signals (Z1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
107
DB31, ...
DBX70.2
REPOS Delay Ackn
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change
0 → 1
The axis was programmed within a traversing block, and the REPOS offset was applied.
Note
A REPOS offset was available for the axis, and REPOSDELAY was active:
DB31, ... DBX10.0 (REPOSDELAY) == 1
This signal behaves the same as:
DB21, ... DBX319.1 - DBX319.3 (Repos Path Mode Ackn)
Signal state 0 or
edge change
1 → 0
The value zero is used to acknowledge that the REPOS offset is not active for this axis. This signal
is cancelled on activation of the remaining block.
Corresponds to ....
DB31, ... DBX10.0 (REPOSDELAY)
DB31, ... DBX72.0 (REPOSDELAY)
DB31, ...
DBX72.0
REPOSDELAY
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change
0 → 1
After a block search, a REPOS offset is applied for this axis. However it is not applied using the
approach block, but rather using the next traversing block in which the axis is programmed.
Signal state 0 or
edge change
1 → 0
The REPOS offset for this axis is not active.
Special cases,
errors, ......
The signal is not relevant for path axes.
Corresponds to ....
DB21, ... DBX31.0 - DBX31.2 (REPOSPATHMODE)
DB31, ... DBX10.0 (REPOSDELAY)
DB31, ... DBX70.2 (REPOS Delay Ackn)
DB31, ...
DBX76.4
Path axis
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change
0 → 1
The axis is involved in the path (path axis).
Note
In conjunction with SERUPRO in status "Target block found", the signal refers to the status of the
axis in the target block.
Signal state 0 or
edge change
1 → 0
The axis is not involved in the path.
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...