Detailed Description
2.2 Travel to fixed stop with analog drives
Basic logic functions: Travel to fixed stop (F1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
35
2.2.2
Travel to fixed stop with hydraulic drives SIMODRIVE 611 digital (HLA module)
Velocity/force control
If the function
FXS
(
FXS[x]=1
) is activated for the hydraulic module 611 digital (HLA
module), only a change from velocity control to force control takes place. Positioning from
the NC is no longer possible in this case.
NC
When traveling to fixed stop, the NC evaluates a torque/force limit acting in addition to the
limits set on the drive:
•
Current
•
Force/torque,
•
Power, pullout power
•
Setup mode
Note
For relevant explanations on velocity control and force control as well as details about
adaptations for SIMODRIVE 611 digital or digital (HLA module), please see:
References:
/FBHLA/ Function Manual HLA module; drive functions firmware
/FB2/ Functional description for Extended Functions, Compensations (K3); Section:
Electronic weight compensation
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...