Detailed description
2.7 Program operation mode
Basic logic functions: Mode group, channel, program operation, reset response (K1)
122
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Bit 2 = 1 is set after operator panel Reset event
Bit 3 = 1 is set after Power-up event
Bit 4 = 1 is set after first start after search run event
For Bit0 = 1 (program event after part program start) the following limitation applies:
If the program event ends with the part program command "RET", then RET always leads
to an executable block (analogous to M17).
There is no new behavior for Bit0 == 0, i.e., RET is interpreted in the interpreter and does
not lead to an "executable block".
No sequences for start/end of part program are passed:
•
If a user ASUB is started from the reset status, the described sequences for the event for
start/end of part program are not passed.
•
Settable Prog-Event properties
Machine data MD20109 $MC_PROG_EVENT_MASK_PROPERTIES can be used to
define further properties of "event-driven program calls" for specific channels in SW 6.3
and higher:
–
Bit0 = 0: An ASUB started from the RESET channel state is followed
by an "event-driven program call" as in earlier versions
–
Bit0 = 1: An ASUB started from the RESET channel state is not followed
by an "event-driven program call"
When part program start:
•
/_N_CMA_DIR/_N_PROG_EVENT_SPF is executed as a subroutine.
_N_PROG_EVENT_SPF must be ended with M17 or RET.
A return by means of REPOS command is not permitted and triggers alarm 16020
"Repositioning not possible".
Errorin the case of operator panel reset or after power-up:
•
If an error is present when the operator panel is reset or after powerup EMERGENCY
STOP or Mode group/NCKContinue, then _N_PROG_EVENT_SPF will only be processed
after EMERGENCY STOP has been acknowledged or the error has been acknowledged
in all channels.
The following always applies to power up:
•
The power up event occurs in all channels at the same time.
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...