Detailed description
2.4 Drive service display (for digital drives only)
Basic logic functions: Diagnostic tools (D1)
24
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Pulse enable (terminal 663)
The display corresponds to the status of terminal 663 (relay: safe operational stop) on the
drive module.
State 1: Module-specific pulse enable
State 0 : module-specific pulse disable
Display corresponds to machine datum:
MD1700 $MD_TERMINAL_STATE
(status of binary inputs).
Setup mode (terminal 112) HMI SW 6.3 and later
The display corresponds to the status of terminal 112 on the SIMODRIVE 611 digital
infeed/regenerative feedback unit.
State 1: Central drive disable for setup mode
State 0 : Central drive enable, no setup mode
Display corresponds to machine datum:
MD1700 $MD_TERMINAL_STATE
(status of binary inputs).
PLC pulse enable
Indicates whether the pulse enable from the PLC is available for the drive.
State 1: The pulses for the drive module have been disabled by the PLC.
State 0: Pulse enable for this drive is activated by the PLC.
Display corresponds to IS DB31, ... DBX21.7 ("Pulse enable")
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
Speed controller enable NC
This display indicates whether the speed controller for the drive has been enabled by the
NC.
State 1: Speed controller enable = OFF
State 0: Speed controller enable = ON
Rampup function generator quick stop
Status display for rampup function generator quick stop.
State 1:
Ramp-up function generator quick stop is not active for the drive.
State 0:
Ramp-up function generator quick stop is active. The drive is stopped without
a ramp function with speed setpoint = 0 and without pulse suppression.
Display corresponds to IS DB31, ... DBX92.1 ("Rampfunction generator rapid stop").
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...