Detailed description
2.12 Block descriptions
Basic logic functions: PLC Basic program powerline (P3 pl)
218
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Description of formal parameters
The table below lists all formal parameters of the YDelta function:
Signal
Type Type
Value range
Remark
YDelta
I
BOOL
= star
= delta.
The changeover edge of the signal
initiates the changeover operation.
SpindleIFNo
I
INT
1..
Number of the axis interface
declared as a spindle
TimeVal
I
S5time
0..
Switchover time
TimerNo
I
INT
10..
Timer for programming the wait
time
Y
Q
BOOL
Energizing of star contactor
Delta
Q
BOOL
Energizing of delta contactor
Ref
I/O
WORD
Instance for status information
Internal use
Call example
CALL FC 17 (
YDelta :=
I 45.7,
//Star delta
SpindleIFNo :=
4,
TimeVal :=
S5T#150ms,
TimerNo :=
10,
//Timer 10
Y :=
Q 52.3,
//Star contactor
Delta :=
Q 52.4,
//Delta contactor
Ref :=
mw 50);
//Instance
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...