Detailed description
2.12 Block descriptions
Basic logic functions: PLC Basic program powerline (P3 pl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
103
Description of formal parameters SINUMERIK 810D, 840D
The table below lists all formal parameters of the RUN_UP function for 810D, 840D:
Signal
I/O
Type
Value range
Remark
MCPNum
I
INT
0 to 2
Number of active MCPs
0: No MCP installed
MCP1In
MCP2In
I
POINTER
I0.0 to I120.0 or F0.0
to F248.0 or DBn
DBX0.0 to DBXm.0
Start address for input
signals of relevant machine
control panel
MCP1Out
MCP2Out
I
POINTER
Q0.0 to Q120.0 or
F0.0 to F248.0 or
DBn DBX0.0 to
DBXm.0
Start address for output
signals of relevant machine
control panel
MCP1StatSend
MCP2StatSend
I
POINTER
Q0.0 to Q124.0,
F0.0 to F252.0 or
DBn DBX0.0 to
DBXm.0
Start address for status double
word for data transmission to the
machine control panel:
DW#16#08000000: Time-out,
otherwise 0
MCP1StatRec
MCP2StatRec
I
POINTER
Q0.0 to Q124.0,
F0.0 to F252.0 or
DBn DBX0.0 to
DBXm.0
Start address for status double
word for data reception by machine
control panel:
DW#16#00000400: Time-out,
otherwise 0
MCP1BusAdr
MCP2BusAdr
I
INT
1...15
Bus address of machine control
panel
MCP1Cycl
MCP2Cycl
I
S5time
Recommendation:
200 ms
Time reference for cyclic updating
of signals to machine control panel
MCPMPI
I
BOOL
1: All machine control panels
connected to the MPI bus
(without GD parameterization)
MCP1Stop
MCP2Stop
I
BOOL
0: Start transfer of machine control
panel signals
1: Stop transfer of machine control
panel signals
MCP1NotSend
MCP2NotSend
I
BOOL
0: Send and receive operation
activated
1: Receive machine control panel
signals only
MCPSDB210
I
BOOL
0: No SDB 210 for MCP
1: Activate timeout monitors on
SDB 210 for MCP
MCPCopyDB77
I
BOOL
1: Copy between DB 77 and MCP
pointers on DB 7
Can only be used with standard
SDB 210 configuration on DB 77.
MCPBusType
I
BYTE
0: MPI or OPI
b#16#33: PROFIBUS for
MCP1 and MCP2
b#16#55: MSTT (i.e. Ethernet)
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...