Detailed description
2.5 Optimization of the control
Basic logic functions: Velocities, Setpoint/Actual Value Systems, Closed-Loop Control (G2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
75
MD32810 fine adjustment
Experience has shown that the initial value is only modified slightly during fine adjustment,
typically by adding or deducting 0.25 ms.
For example, if the initial value is 1.5 ms, the optimum value calculated manually is usually
within the range 1.25 ms to 1.75 ms.
In the case of axes equipped with direct measuring systems (load encoders) and strong
elasticity, you may possibly accept small overshoots of some micrometers.
These can be reduced with the help of the position setpoint filter for dynamic response
adaptation
(MD32910 $MA_DYN_MATCH_TIME) and for jerk (MD32410 $MA_AX_JERK_TIME),
which also reduces the axis speed.
Identical axis data within an interpolation group
All the axes within an interpolation group must have identical settings in the following data:
MD32200 $MA_POSCTRL_GAIN
MD32620 $MA_FFW_MODE
MD32610 $MA_VELO_FFW_WEIGHT
MD32810 $MA_EQUIV_SPEEDCTRL_TIME (or MD32800 $MA_EQUIV_CURRCTRL_TIME)
MD32400 $MA_AX_JERK_ENABLE
MD32402 $MA_AX_JERK_MODE
MD32410 $MA_AX_JERK_TIME
The servo gain display (K
V
) in the axis service screen form is used for checking.
If identical values are not possible for the above data,
machine data:
MD32910 $MA_DYN_MATCH_TIME
can be used to make an adjustment.
This allows the same servo gain value (K
V
) to be displayed;
however, this rarely occurs.
Different servo gain values (K
V
) usually point to the following:
•
The gear ratios do not match in one or several axes.
•
The feedforward control setting data do not match.
•
The jerk filter setting data is incorrect at some point.
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...