Detailed description
2.7 Program operation mode
Basic logic functions: Mode group, channel, program operation, reset response (K1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
125
2.7.12
Control and effect on stop events
Controlling stop events
Stop events can be controlled for a particular program area in a program section. This
program section is designated as a stop-delay section and is activated/deactivated via
language commands:
•
Activation: DELAYFSTON
•
Deactivate: DELAYFSTOF
References:
/PGA/ Programming Manual Advanced
NCK events that can be stopped on short notice and whose reaction can result in the stop
delay area for a program section are evaluated according to the following criteria:
•
Immediate
Stops immediately even in the stop delay area. Is known as a "hard stop event".
•
Delayed
Stop (even a short term stop) takes place after the stop delay area. Is known as a "soft
stop event".
•
Alarm 16954
Program is aborted because illegal program commands have been used in the stop delay
area.
•
Alarm 16955
Program is resumed because an illegal action has taken place in the stop delay area.
•
Alarm 16957
The program area (stop delay area) enclosed by DELAYFSTON and DELAYFSTOF
could not be activated. As a result, every stop will take effect immediately and is not
subject to a delay! This will always occur when the deceleration begins before the stop
delay area but ends within the stop delay area. Likewise, if the stop delay area is entered
with an override of 0, the stop delay area also cannot be activated. (example: a G4 before
the stop delay section allows the user to reduce the override to 0. The next block in stop
delay area then starts with Override 0 and the described alarm situation occurs.)
MD11411 $MN_ENABLE_ALARM_MASK (activation of warnings), Bit 7 activates this
alarm.
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...