Detailed Description
2.3 Configurable gear adaptation
Basic logic functions: Spindles (S1)
42
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Note
The number of servo parameter sets for the mechanical factors remain unchanged.
Furthermore, five mechanical gear steps for the spindle and one for the axis operation can
be configured.
As the speed limits of each gear step are dependent on the mechanical factors, the following
machine data can be configured only for one gear step data set for each gear step:
MD35130 $MA_GEAR_STEPMAX_VELO_LIMIT[n] ; Limit of maximum speed
MD35130 $MA_GEAR_STEPMAX_VELO_LIMIT[n] ; Increase to the minimum speed for M3,
M4
Changing parameter sets and formatting
The gear step change also switches over the servo parameter set,
if machine data:
MD35590 $MA_PARAMSET_CHANGE_ENABLE = 0 or 1
.
0:
The parameter sets cannot be controlled.
1:
The servo parameter set is defined primarily by the internal NC switchover at the VDI
interface.
If the parameter sets cannot be controlled:
•
For axes, the 1st parameter set with the index 0 is always the one that is applicable.
•
For spindles, the 2nd to the 6th parameter set plus one is always active depending on the
gear step selected.
By pre-setting of servo parameter set through VDI interface, the parameter sets 1 to 6 can
be activated with the index 0 to 5.
The following applies:
•
For the axes involved, the parameter set number that corresponds to the master spindle
gear step incremented by one is active. This then corresponds to parameter set numbers
2 to 6.
•
For spindles, the 2nd to the 6th parameter set plus one is always active depending on the
gear step selected.
If:
MD35590 $MA_PARAMSET_CHANGE_ENABLE = 2,
the servo parameter set is specified by the PLC.
A gear step can be specified by the PLC at any time.
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...