Description of formal parameters
The table below lists all formal parameters of the PART_AX function:
Signal
I/O
Type
Value range
Remark
Start
I
BOOL
AxisNo
I
INT
1 - 31
No. of axis to be traversed
IC
I
BOOL
Directional data
0 = absolute
1 = incremental
DC
I
BOOL
0 = specified direction
1 = shortest path
when DC = 1 the parameters IC,
Minus, Plus must be = 0
Minus
I
BOOL
0 : Rotary axis motion as for linear
axis
1: Motion in negative direction with
rotary axes
Plus
I
BOOL
0 : Rotary axis motion as for linear
axis
1: Motion in positive direction with
rotary axes
Pos
I
INT
0 to +32767
No. of indexing position
FRate
I
REAL
± 0,1469368 E -38 to
± 0,1701412 E +39
Feedrate of
linear axis: mm/min
Rotary axis: deg/min
InPos
A
BOOL
1 = In position
Active
A
BOOL
1 = Active
StartErr
A
BOOL
Axis cannot be started.
Error
A
BOOL
Error during traversing
1)
1)
Error evaluation by user in the PLC
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...