Detailed Description
2.1 Various interface signals and functions (A2)
Basic logic functions: NC/PLC interface signals (Z1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
21
DB19
DBX20.3
Cancel alarm cleared
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change 0 → 1
Cancel alarm deleted active
Signal state 0 or
edge change 1 → 0
Cancel alarm deleted inactive
DB19
DBX20.4
Recall alarm cleared
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change 0 → 1
Recall alarm deleted inactive
Signal state 0 or
edge change 1 → 0
Recall alarm deleted inactive
DB19
DBX20.6
Simulation selected
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change 0 → 1
On entry to simulation = 1
Signal state 0 or
edge change 1 → 0
On exit from simulation = 0
Application
example(s)
Can be evaluated by machine manufacturer in order to activate the test on NC start.
The following must be set in the drive machine data:
MD1012 $MD_FUNC_SWITCH, bit 2 = 0.
Status "Ext. pulse disable active, terminal 663 open" is then not transmitted to the NC.
Corresponding to .... MD1012 $MD_FUNC_SWITCH, bit 2
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...