Detailed description
2.12 Block descriptions
Basic logic functions: PLC Basic program powerline (P3 pl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
169
Description of formal parameters
The following table shows all formal parameters of the SI relay function.
Formal parameters of SI relay function
Signal
Type
Type
Remark
In1
I
BOOL
Input 1
In2
I
BOOL
Input 2
In3
I
BOOL
Input 3
Ackn1
I
BOOL
Acknowledge input 1
Ackn2
I
BOOL
Acknowledge input 2
TimeValue1 I
TIME
Time value 1 for OFF delay
TimeValue2 I
TIME
Time value 2 for OFF delay
TimeValue3 I
TIME
Time value 3 for OFF delay
Out0
A
BOOL
Output, instantaneous (no delay)
Out1
A
BOOL
Output, delayed by TimeValue1
Out2
A
BOOL
Output, delayed by TimeValue2
Out3
A
BOOL
Output, delayed by TimeValue3
FirstRun
I/O
BOOL
Activation of initial state
Note
The block must be called cyclically by the user program once following SPL program startup.
The user must provide an instance DB with any number for this purpose. The call is multi-
instance-capable.
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...