Detailed description
2.12 Program runtime/workpiece counter
Basic logic functions: Mode group, channel, program operation, reset response (K1)
204
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Activation
The workpiece counters are activated or the reset timing and counting algorithm are
specified via the following two channel-specific machine data:
MD27880 $MC_PART_COUNTER (activation of workpiece counters)
Bit
Value Significance
0
1
$AC_REQUIRED_PARTS is active
0
Alarm/VDI output with: $AC_REQUIRED_PARTS == $AC_ACTUAL_PARTS
1
1
Alarm/VDI output with: $AC_REQUIRED_PARTS == $AC_SPECIAL_PARTS
4
1
$AC_TOTAL_PARTS is active
5
1
With M2 / M30: $AC_TOTAL= 1
6
1
Equality under M function of $MC_PART_COUNTER_MCODE[ 0 ]: $AC_TOTAL= 1
8
1
$AC_ACTUAL_PARTS is active
0
With M2 / M30: $AC_ACTUAL= 1
9
1
Equality under M function of $MC_PART_COUNTER_MCODE[ 1 ]: $AC_ACTUAL= 1
12
1
$AC_SPECIAL_PARTS is active
0
With M2 / M30: $AC_SPECIAL= 1
13
1
Equality under M function of $MC_PART_COUNTER_MCODE[ 2 ]: $AC_SPECIAL= 1
MD27882 $MC_PART_COUNTER_MCODE[ <Index> ] (workpiece counting via user-specific M function)
Index
Significance
0
Value of M function with which $AC_TOTAL_PARTS is counted up.
1
Value of M function with which $AC_ACTUAL_PARTS is counted up.
2
Value of M function with which $AC_SPECIAL_PARTS is counted up.
Boundary conditions
•
All workpiece counters are set to the default values on control power-up and can be read
and written independent of their activation.
•
If $AC_REQUIRED_PARTS = 0, no ID check is performed with the counter pulse for
$AC_ACTUAL_PARTS or $AC_SPECIAL_PARTS even if the MD bit is set.
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...