Detailed Description
2.1 Spindle modes
Basic logic functions: Spindles (S1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
31
Table 2-2
Switch back to spindle mode
C=...
M71
→ Output to PLC
Closed-loop controller enable off (by PLC)
Switch actuator (by PLC)
Switched to spindle parameter set (1-5) internally in the NC,
controller enable on (by PLC)
M3/4/5
or
SPOS=...
NC travels with spindle parameter set
Change to spindle mode
The interpolation parameter (set 1 ... 5) is selected according to the currently valid gear step.
The feedforward control function is always activated, except for tapping with compensating
chuck.
Machine data:
MD32620 $MA_FFW_MODE (feedforward control type)
must always be not equal to 0.
Feedforward control should always be operated with the value 100% to avoid alarms being
output during positioning.
$[LVPRGH
6SLQGOHPRGH
'HSHQGLQJRQJHDUVWHS
3DUDPHWHUVHW
9DOLG
9DOLG
9DOLG
9DOLG
9DOLG
9DOLG
Figure 2-4
Validity of parameter sets for axis and spindle modes
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...