Detailed Description
2.5 Programming
Basic logic functions: Spindles (S1)
78
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Constant cutting rate setting
Constant cutting speed specifications from part program, FC18 or synchronized actions are
programmed in setting data:
SD43200 $SA_SPIND_S
and always programmed from the usual sources.
Read SD43202
The constant cutting speed is read from setting data:
SD43202 $SA_SPIND_CONSTCUT_S [m/min] or [feet/min]
with the positive edge of the start signal:
DB31, ... DBX30.1 (Spindle start CW)
and
DB31, ... DBX30.2 (Spindle start CCW).
Note
Rewriting of the setting data is not activated until the next positive edge of the start signals:
DB31, ... DBX30.1 (Spindle start CW)
and
DB31, ... DBX30.2 (Spindle start CCW)
for the current spindle speed.
The content of the setting data is only accepted with the next spindle start signal.
Supplementary condition
To ensure that constant cutting rate settings are active, the spindle concerned must be a
master spindle in the channel handling the spindle.
This condition is met when NC/PLC IS:
DB31, ... DBX84.0 = 1 (Constant cutting rate active)
is set on the axial VDI interface.
Writing from the part program
When writing from the part program, the value for the constant cutting rate is interpreted as
follows:
if
G710
is active in the 12th
G
Group:
Metric
if
G700
is set in the 12th
G
Group:
inch as [feet/min]
Regarding
G70
,
G71
and the specification of external (HMI), the setting in the machine data:
MD10240 $MN_SCALING_SYSTEM_IS_METRIC
determines the interpretation of the specified values.
Further explanations regarding metric/inch measuring system can be found under:
Literature:
/FB1/ Function Manual, Basic Functions; Speeds, Setpoint-/Actual Value System, Control
(G2)
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...