Detailed description
2.12 Block descriptions
Basic logic functions: PLC basic program solution line (P3 sl)
102
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Signal
Type Type
Range of values
Remark
MCP1NotSend
MCP2NotSend
I
BOOL
0: Send and receive operation
activated
1: Receive machine control panel
signals only
MCPSDB210
I
BOOL
false
Available owing to compatibility
MCPCopyDB77
I
BOOL
false
Available owing to compatibility
MCPBusType
I
BYTE
b#16#33: Profibus
b#16#55: Ethernet
Mixed operation possible, see
MCP/HHU configuration
HHU
I
INT
0, 5
Handheld unit interface
0: No HHU
5: HHU on Ethernet
BHGIn
I
POINTER
I0.0 to I124.0,
F0.0 to F252.0 or
DBn DBX0.0 to
DBXm.0
Start address
PLC receive data
from HHU
BHGOut
I
POINTER
Q0.0 to Q124.0,
F0.0 to F252.0 or
DBn DBX0.0 to
DBXm.0
Start address
PLC transmit data
to HHU
BHGStatSend
I
POINTER
Q0.0 to Q124.0,
F0.0 to F252.0 or
DBn DBX0.0 to
DBXm.0
Available owing to compatibility
BHGStatRec
I
POINTER
Q0.0 to Q124.0,
F0.0 to F252.0 or
DBn DBX0.0 to
DBXm.0
Available owing to compatibility
BHGInLen
I
BYTE
HHU default:
B#16#6 (6 Byte)
Available owing to compatibility
BHGOutLen
I
BYTE
HHU default:
B#16#14 (20 Byte)
Available owing to compatibility
BHGTimeout
I
S5time
Recommendation:
700 ms
Available owing to compatibility
BHGCycl
I
S5time
Recommendation:
100 ms
Available owing to compatibility
BHGRecGDNo
I
INT
HHU default: 2
Ethernet DIP switch
BHGRecGBZNo
I
INT
HHU default: 2
Available owing to compatibility
BHGRecObjNo
I
INT
HHU default: 1
Available owing to compatibility
BHGSendGDNo
I
INT
HHU default: 2
Available owing to compatibility
BHGSendGBZNo I
Int
HHU default: 1
Available owing to compatibility
BHGSendObjNo
I
INT
HHU default: 1
Available owing to compatibility
BHGMPI
I
BOOL
false
Available owing to compatibility
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...