Detailed description
2.6 Block search Type 5 SERUPRO
Basic logic functions: Mode group, channel, program operation, reset response (K1)
72
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
2.6.2
Acceleration measures via MD
Machine data settings
The processing speed of the entire SERUPRO operation can be accelerated using the
following machine data.
MD22600 $MC_SERUPRO_SPEED_MODE and
MD22601 $MC_SERUPRO_SPEED_FACTOR
With MD22600 $MC_SERUPRO_SPEED_MODE == 1, the SERUPRO operation will run at
the usual "dry run feedrate".
Through MD22600 $MC_SERUPRO_SPEED_MODE == 0,
MD22601 $MC_SERUPRO_SPEED_FACTOR is evaluated,
and additional acceleration is permitted. Dynamic monitoring functions are disabled in this
mode.
SPEED factor for channel axes during ramp-up
Machine data MD22600 $MC_SERUPRO_SPEED_MODE is effective for the following
channel axes in the main run throughout the entire SERUPRO operation:
•
PLC axes
•
Command axes
•
Positioning axes
•
Reciprocating axes
The functions of MD22600 $MC_SERUPRO_SPEED_MODE and
MD22601 $MC_SERUPRO_SPEED_FACTOR apply only to SERUPRO and not to program
testing. In this case no axes/spindles are moved.
Caution
The NC as a discrete system generates a sequence of interpolation points.
It is possible that a synchronized action that was triggered in normal operation will no longer
be triggered in SERUPRO.
Mode of functioning with DryRun
An active SERUPRO SPEEDFACTOR has the following effect on DryRun:
•
DryRun is activated simultaneously.
This causes a switch from
G95/G96/G961/G97/G971
to
G94
in order to execute
G95/G96/G961/G97/G971
as quickly as you wish.
•
Tapping and thread cutting are performed at the usual velocity for DryRun.
DryRun and SERUPRO affect the spindle/axis with the following G codes:
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...