Detailed description
2.5 NC block compressor COMPON, COMPCURV, -CAD
Basic logic functions: Continuouspath Mode, Exact Stop, LookAhead (B1)
52
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Activating the MD values
The new values are activated after the
NewConfig
command.
The rounding function
G642
and jerk limitation
SOFT
can be used to achieve further
improvements in surface quality. These commands must be entered at the start of the
program:
COMPCAD SOFT G642
COMPOF
terminates the compressor function.
All blocks are compressed for which a simple syntax is sufficient:
N
...
G1X
...
Y
...
Z
...
F
...
where "..." is a number and X, Y, Z are axis names.
Including blocks with e.g., extended addresses such as
C=100
or
A=AC(100)
or blocks with
auxiliary functions.
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...