Detailed description
2.2 Zeros and reference points
Basic logic functions: Axes, coordinate systems, frames (K2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
37
2.2.2
Position of coordinate systems and reference points
Control POWER ON
For incremental measuring probes, the reference point must be approached each time the
control is activated so that the control can transfer all position values to the coordinate
system.
=
0
0
;
0DFKLQH
FRRUGLQDWH
V\VWHP0&6
0DFKLQH
]HUR
6SLQGOH
:RUNSLHFH
OHQJWK
:RUNSLHFH
FRRUGLQDWH
V\VWHP:&6
:RUNSLHFH
]HUR
Figure 2-8
Position of coordinate systems by machine zero M and workpiece zero W
0DFKLQH
]HUR
5HIHU
HQFH
SRLQW
7RROKROGHU
7RROKROGHUUHIHUHQFHSRLQW
7
/
/
5
=
;
=
0
;
Figure 2-9
Position of reference point in relation to machine zero
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...