Detailed description
2.2 Functions
Basic logic functions: Various NC/PLC interface signals and functions (A2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
33
Dynamic response
Involutes that begin or end on the base circle have an infinite curvature at this point. To
ensure that the velocity is adequately limited at this point when tool-radius compensation is
active, without reducing it too far at other points, the "Velocity limitation profile" function must
be activated:
MD28530 $MC_MM_PATH_VELO_SEGMENTS > 1 (number of memory elements for
limiting the path velocity)
A setting of 5 is recommended. This setting need not be made if only involute sections are
used, which have radii of curvature that change over a relatively small area.
2.2.3
Activate DEFAULT memory
GUD start values
The DEF... / REDEF... NC commands can be used to assign default settings to global user
data (GUD). These default settings must be permanently stored in the system if they are to
be available after certain system states (e.g. RESET).
The memory space for this is taken from the memory area that was assigned via the
machine data:
MD18150 $MM_GUD_VALUES_MEM (number of additional parameters according to
MD18170)
The setting for activating the stored default values is made in machine data:
MD11270 $MN_DEFAULT_VALUES_MEM_MASK (activation default values for NC
language elements)
References:
/FB1/Function Manual Basic functions; S7: "Memory Configuration"
/PGA/ Programming Guide Advanced
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...