Detailed Description
2.1 Various interface signals and functions (A2)
Basic logic functions: NC/PLC interface signals (Z1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
55
DB31, ...
DBX94.1
Heatsink temperature prewarning
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change
0 → 1
The drive module sends the warning "heatsink temperature prewarning" to the PLC.
This triggers the following:
•
Terminal 5 on the infeed/regenerative feedback module is simultaneously activated.
•
The drive module is switched off after 20 seconds. The drives are stopped when the impulse
enable is removed. Then alarm 300515 is triggered.
Signal state 0 or
edge change
1 → 0
The drive module heatsink temperature pre-warning has not responded.
Application
example(s)
As soon as "heatsink temperature prewarning" has been signaled, the PLC can, for example,
initiate controlled shutdown of the drives.
Additional references /DA/ Diagnostics Guide
DB31, ...
DBX94.2
Ramp-up completed
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change
0 → 1
The PLC is signaled, that after a new speed setpoint has entered, the speed actual value has
reached the speed tolerance bandwidth:
MD1426 $MD_SPEED_DES_EQ_ACT_TOL (tolerance bandwidth for n
set
= n
act
- signal)
and has remained within this tolerance bandwidth for at least the time defined using machine data:
MD1427 $MD_SPEED_DES_EQ_ACT_DELAY (delay time n
set
= n
act
- signal)
refer to the diagram).
Even if the speed actual value leaves the tolerance band (because of speed fluctuations resulting
from changes in load) the "rampup completed" signal remains (1 signal).
Signal state 0 or
edge change
1 → 0
The conditions described above have not yet been fulfilled. The rampup has therefore not yet been
completed.
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...