Data lists
5.1 Machine data
Basic logic functions: Axis monitoring, protection zones (A3)
80
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Number
Identifier: $MC_
Description
24436
TRAFO_INCLUDES_TOOL_5
Tool handling with active transformation 5.
24446
TRAFO_INCLUDES_TOOL_6
Tool handling with active transformation 6.
24456
TRAFO_INCLUDES_TOOL_7
Tool handling with active transformation 7.
24466
TRAFO_INCLUDES_TOOL_8
Tool handling with active transformation 8.
24476
TRAFO_INCLUDES_TOOL_9
Tool handling with active transformation 9.
24486
TRAFO_INCLUDES_TOOL_10
Tool handling with active transformation 10.
28600
MM_NUM_WORKAREA_CS_GROUPS
Number of coordinate system-specific working area
limitations
Protection zones
Number
Identifier: $MC_
Description
28200
MM_NUM_PROTECT_AREA_CHAN
Number of files for channelspecific protection zones
28210
MM_NUM_PROTECT_AREA_ACTIVE
Number of simultaneously active protection zones in
one channel
28212
MM_NUM_PROTECT_AREA_CONTUR
Elements for active protection zones (DRAM)
5.1.3
Axis/spindlespecific machine data
Axis monitoring
Number
Identifier: $MA_
Description
30310
ROT_IS_MODULO
Modulo conversion for rotary axis and spindle
30800
WORK_AREA_CHECK_TYPE
Type of checking of working area limits
32200
POSCTRL_GAIN [n]
Servo gain factor
32250
RATED_OUTVAL
Rated output voltage
32260
RATED_VELO
Rated motor speed
32300
MAX_AX_ACCEL
Axis acceleration
32800
EQUIV_CURRCTRL_TIME
Equivalent time constant current control loop for feedforward control
32810
EQUIV_SPEEDCTRL_TIME
Equivalent time constant speed control loop for feedforward control
32910
DYN_MATCH_TIME [n]
Time constant for dynamic matching
35160
SPIND_EXTERN_VELO_LIMIT
Spindle speed limitation via PLCC
36000
STOP_LIMIT_COARSE
Exact stop coarse
36010
STOP_LIMIT_FINE
Exact stop fine
36020
POSITIONING_TIME
Time delay exact stop fine
36030
STANDSTILL_POS_TOL
Zero speed tolerance
36040
STANDSTILL_DELAY_TIME
Delay time zero-speed monitoring
36050
CLAMP_POS_TOL
Clamping tolerance with IS "Clamping active"
36052
STOP_ON_CLAMPING
Special functions for clamped axis
36060
STANDSTILL_VELO_TOL
Maximum velocity/speed "Axis/spindle stationary"
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...