Detailed Description
2.3 Configurable gear adaptation
Basic logic functions: Spindles (S1)
48
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Spindle response after a gear step change
How the spindle behaves once the gear step has been changed depends on the following
initial conditions:
•
If the spindle was in the stop state before the gear step change (
M5
, FC18: "Stop rotate
spindle"), in positioning or axis mode,
M5
(spindle stop) is active after completion of the
gear step change.
•
If a direction of rotation
(
M3
,
M4
, or FC18: "Start spindle rotation"), then the last speed and direction of rotation will
become active again after the gear step change. In the new gear step, the spindle
accelerates to the last spindle speed programmed (
S
value).
The next block in the part program can be executed.
Special points to be noted
The following points must be observed on gear step change:
•
The gear step change is not terminated by selecting
NC/PLC IS:
DB31, ... DBX20.1 (Ramp-up switchover to V/f mode).
Setpoint 0 is output.
The acknowledgment of the gear step change is carried out as usual
by the NC/PLC IS:
DB31, ... DBX16.3 (Gear changed).
•
The "Rampfunction generator rapid stop" signal must be reset by the PLC before the gear
step change is completed by the PLC.
•
The gear step change procedure is terminated without an alarm output on an NC reset.
The gear step output with NC/PLC IS:
DB31, ... DBX16.0-16.2 (Actual gear step A to C)
is applied by the NC.
Star/delta switchover with FC17
Digital main spindle drives can be switched in both directions between star and delta using
FC17, even when the spindle is running. This automatic switchover is controlled by a defined
logic circuit in FC17, which provides the user with a configurable switchover time for the
relevant spindle.
Further instructions on function block FC17 can be found under:
Literature:
/FB1/ Function Manual Basic Functions; PLC Basic Program (P3)
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...