Detailed Description
2.9 Mode group, channel, program operation, reset response (K1)
Basic logic functions: NC/PLC interface signals (Z1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
97
DB21, ...
DBX35.0
Program status running
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change
0 → 1
The part program was started with the interface signal:
DB21, ... DBX7.1 (NC start)
and is running.
The running program was stopped with the interface signal:
DB21, ... DBX6.1 (read-in disable)
Signal state 0 or
edge change
1 → 0
•
Program stopped by
M00
/
M01
or NC stop or operating mode change.
•
If single block mode, the block is processed.
•
End of program reached (
M02
/
M30
).
•
Program aborted due to a reset.
•
No actual block in the memory (e.g., for MDA).
•
The actual block cannot be executed.
Signal irrelevant for
...
The part program was started with the interface signal:
DB21, ... DBX7.1 (NC start)
and is running.
Special cases,
errors, ......
The interface signal:
DB21, ... DBX35.0 (program status running)
does not change to 0 if workpiece machining is stopped due to the following events:
•
A feed disable or spindle disable was output
•
DB21, ... DBX6.1 (read-in disable)
•
Feed correction to 0%
•
The spindle and axis monitoring functions respond
•
Position setpoints are entered in the NC program for axes in "follow-up mode," for axes without
"servo enable," or for "parking axes"
Corresponds to ....
DB21, ... DBX6.1 (read-in disable)
DB21, ...
DBX35.1
Program status wait
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change
0 → 1
The running program is waiting for the program command
WAIT_M
or
WAIT_E
in an NC block. The
wait condition specified in the
WAIT
command for the channel or channels has not yet been fulfilled.
Signal state 0 or
edge change
1 → 0
Program status wait is not active.
Further references
/PG/Programming Fundamentals Guide
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...