Detailed description
2.12 Block descriptions
Basic logic functions: PLC Basic program powerline (P3 pl)
162
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Declaration of function
FUNCTION_BLOCK FB 9
VAR_INPUT
Ack :
BOOL ;
//Acknowledge interrupts
OPMixedMode:
BOOL:= FALSE;
//Mixed operation with non-M-to-N-enabled OP
//deactivated
ActivEnable:
BOOL:= TRUE;
// Not supported.
//Control panel switchover Interlocking via
//MMCx_SHIFT_LOCK in DB 19
MCPEnable :
BOOL:= TRUE;
// Activate MCP switchover
END_VAR
VAR_OUTPUT
Alarm1 :
BOOL ;
// Interrupt: Error in HMI bus address, bus type!
Alarm2 :
BOOL ;
// Interrupt: No confirmation MMC_1 offline!
Alarm3 :
BOOL ;
// Interrupt: MMC_1 is not going offline!
Alarm4 :
BOOL ;
// Interrupt: No confirmation MMC_2 offline!
Alarm5 :
BOOL ;
// Interrupt: MMC_2 is not going offline!
Alarm6 :
BOOL ;
// Interrupt: Queuing MMC is not going online!
Report :
BOOL ;
// Message: Sign-of-life monitoring MMC
ErrorMMC :
BOOL ;
// Error detection MMC
END_VAR
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...