Detailed description
2.12 Block descriptions
Basic logic functions: PLC Basic program powerline (P3 pl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
133
PI service: SETUDT
Set function current user data active
The current user data, such as tool offsets, basic frames and settable frames are set to
active in the next NC block (only in STOP state).
Parameterization
Signal
Type
Value range
Meaning
PIService
ANY
PI.SETUDT
Activate user data
Unit
INT
1 to 10
Channel
WVar1
WORD
1 to 5
User data type
1 = active tool offset
2 = active basic frame
3 = active settable frame
4 = active global basic frame
5 = active global settable frame
WVar2
WORD
0
Standby
WVar3
WORD
0
Standby
PI service: SETUFR
Activate function user frames:
User frames are loaded to the NCK. All necessary frame values must be transferred to the
NCK beforehand by writing variables with FB 3.
Parameterization
Signal
Type
Value range
Meaning
PIService
ANY
PI.SETUFR
Activate
user frames
Unit
INT
1 to 10
Channel
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...