Detailed description
2.6 Block search Type 5 SERUPRO
Basic logic functions: Mode group, channel, program operation, reset response (K1)
56
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Identification of the active SERUPRO in the interface.
DB21, ... DBX318.1
The VDI signal of the NCK channel (NCK→PLC):
DB21, ... DBX318.1 (block search via program test is active)
has the following meaning and effect:
The NC runs in the internal "Program test" mode until the target block of the search is
activated in the main run and the program status changes to "Stopped".
During this time, interface "Block search via program test is active" is set to 1.
For userdefined ASUB after the SERUPRO operation
Note
If the machine manufacturer decides to start an ASUB after the SERUPRO operation as
described in item 7, the following must be observed:
Stopped status acc. to point 6. :
Machine data:
MD11602 $MN_ASUP_START_MASK
and
MD11604 $MN_ASUP_START_PRIO_LEVEL
allow the NCK to start the ASUB from stopped status automatically via the FC9 block.
Acknowledgement of FC9 only after completion of REPOS block:
The ASUB can only be signaled as complete from the FC9 block with "ASUB Done" if the
REPOS block has also been completed.
Deselection of assigned REPOS operation after Item 8:
The start of the ASUB deselects the assigned REPOS operation!
Therefore, the ASUB should be ended with REPOSA in order to retain the REPOS
operation.
Deleting an unwanted REPOS operation:
The unwanted REPOS operation is deleted by completing the ASUB with
M17
or
RET
.
Special handling of ASUB:
As a basic rule, an ASUB that ends with REPOS and is started from stopped status receives
special treatment.
The ASUB stops automatically before the REPOS block and indicates this via:
DB21, ... DBX318.0 (ASUB stopped)
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...