Detailed description
2.6 Block search Type 5 SERUPRO
Basic logic functions: Mode group, channel, program operation, reset response (K1)
68
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Valid REPOS offset
When the SERUPRO operation is complete, the user can read out the REPOS offset via the
axis/spindle VDI signal (NCK→PLC):
DB31, ... DBX70.0 (REPOS offset).
The effects of this signal on the relevant axis are as follows:
Value 0:
No REPOS offset is applied.
Value 1:
REPOS offset is applied.
Range of validity
The interface signal:
DB31, ... DBX70.0 (REPOS offset)
is supplied at the end of the SERUPRO operation.
The REPOS offset is invalidated at the start of a SERUPRO ASUB or the automatic ASUB
start.
Updating the REPOS offset within the scope
Between the SERUPRO end and SERUPRO start, the axis can be moved in JOG mode with
a mode change.
The user applies the REPOS offset manually with JOG, in order to set the IS
DB31, ... DBX70.0 (REPOS offset) to the value 0.
In the scope, the axis can also be moved via FC18, where the IS
DB31, ... DBX70.0 (REPOS offset) is constantly updated.
Displaying the range of validity
The range of validity of the REPOS offset is indicated with interface signal:
DB31, ... DBX70.1 (REPOS offset valid)
It is indicated whether the REPOS offset calculation was valid or invalid:
Value 0:
The REPOS offset of this axis is calculated correctly.
Value 1:
The REPOS offset of this axis cannot be calculated, as the REPOS has not
yet occurred, e.g., it is at the end of the ASUB, or no REPOS is active.
REPOS offset after an axis replacement
With the group signal:
DB21, ... DBX319.5 (Repos DEFERRAL Chan)
can be used to determine whether a valid REPOS offset has taken place:
Value 0:
All axes currently controlled by this channel have either no REPOS offset or
their REPOS offsets are invalid.
Value 1:
Miscellaneous.
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...