Basic logic functions: Feeds (V1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
63
Examples
4
4.1
Feedrate programming for chamfer/rounding FRC, FRCM
Example 1: Following block feedrate
MD20201 CHFRND_MODE_MASK Bit0 = 0
(apply feedrate from following block; default setting)
N10
G0 X0 Y0 G17 F100 G94
N20
G1 X10 CHF=2
; Chamfer N20-N30 with F=100 mm/min
N30
Y10 CHF=4
; Chamfer N30-N40 with FRC=200 mm/min
N40
X20 CHF=3 FRC=200
; Chamfer N40-N60 with FRCM=50 mm/min
N50
RNDM=2 FRCM=50
N60
Y20
; Modal rounding N60-N70
with
FRCM=50 mm/min
N70
X30
; Modal rounding N70-N80
with
FRC=100 mm/min
N80
Y30 CHF=3 FRC=100
; Chamfer N80-N90 with
FRCM=50 mm/min
(modal)
N90
X40
; Modal rounding N90-N100 with
F=100 mm/min (deselect FRCM)
N100
Y40 FRCM=0
; Modal rounding N100-N120
with G95
FRC=1 mm/rev
N110
S1000 M3
N120
X50 G95 F3 FRC=1
...
M02
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...