Detailed description
2.12 Block descriptions
Basic logic functions: PLC Basic program powerline (P3 pl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
127
Error identifiers
If it was not possible to execute a job, the failure is indicated by "logic 1" on status parameter
error. The error cause is coded at the block output State:
State
Meaning
Note
3
Negative acknowledgment, job
not executable
Internal error, any help:
NC RESET
6
FIFO full
Job must be repeated since queue is full
7
Option not set
BP parameter "NCKomm" is not set
9
Transmission occupied
Job must be repeated
Pulse diagram
'RQH
5HT
(UURU
(1)
Activation of function
(2)
Positive acknowledgment: PI service has been executed
(3)
Reset function activation after receipt of acknowledgment
(4)
Signal change by means of FB
(5)
If function activation is reset prior to receipt of acknowledgment, the output signals are not
updated without the operational sequence of the activated function being affected.
(6)
Negative acknowledgment: Error has occurred, error code in the output parameter State
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...