Detailed Description
2.1 Various interface signals and functions (A2)
Basic logic functions: NC/PLC interface signals (Z1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
49
DB31, ...
DBX93.0 - DBX93.2
Active drive parameter set A, B, C
Edge evaluation: no
Signal(s) updated: cyclic
Meaning
The drive module (611D/611U) signals back to the PLC which drive parameter set is currently
active.
With bit combinations A, B and C, 8 different drive parameter sets can be selected for the 611D.
The following assignment applies:
DFWLYHGULYHSDUDPHWHUVHW
&
%
$
Application
example(s)
Drive parameter switchover can be used for the following:
•
To change the gear stage
•
To change over the measuring circuit
Corresponding to .... DB31, ... DBX21.0 - DBX21.2 (drive parameter set selection)
Additional references DB31, ... DBX21.0 - DBX21.2 (drive parameter set selection)
or
/IAD/ SINUMERIK 840D Installation and Start-up Guide; Chapter: SIMODRIVE 611D
or
/IAC/ SINUMERIK 810D Installation and Start-up Guide
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...