Detailed description
2.3 Feedrate control
Basic logic functions: Feeds (V1)
54
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
•
The selected servo parameter set
A parameter set describes the most important setting options for control purpose in the
servo.
It comprises, e.g., the following axis-specific/spindle-specific machine data:
31050 DRIVE_AX_RATIO_DENOM[n]
Parameter set n for 0 to 5
31060 DRIVE_AX_RATIO_NUMERA[n]
Parameter set n for 0 to 5
32200 POSCTRL_GAIN[n]
Parameter set n for 0 to 5
32452 BACKLASH_FACTOR[n]
Parameter set n for 0 to 5
32610 VELO_FFW_WEIGHT[n]
Parameter set n for 0 to 5
32800 EQUIV_CURRCTRL_TIME[n]
Parameter set n for 0 to 5
32810 EQUIV_SPEEDCTRL_TIME[n]
Parameter set n for 0 to 5
32910 DYN_MATCH_TIME[n]
Parameter set n for 0 to 5
36012 STOP_LIMIT_FACTOR[n]
Parameter set n for 0 to 5
36200 AX_VELO_LIMIT[n]
Parameter set n for 0 to 5
For more information about parameter sets and programming, please refer to:
References:
/FB1/ Function Manual, Basic Functions; Velocities, Setpoint/Actual Value Systems, Closed-
Loop Control (G2)
/PG/ Programming Guide, Fundamentals; Path Response and Feedrate Control
Dynamic criteria and feedforward control
With dynamic response criteria, it must be distinguished from where they were set:
•
In the part program
or
•
From a main-run interpolation (synchronized action or PLC default)
Note
Changes in the dynamic response made in a part program do not affect command axis or
PLC axis movements.
Changes from synchronized actions do not affect the movements from a part program.
Travel with feedforward control ON/OFF
The type of feedforward control and the path axes to which feedforward is to be applied are
determined:
•
Programmable in the part program with
FFWON
/
FFWOF
for axes selected using machine
data.
•
Only indirectly programmable in synchronized actions (
ASUB
).
•
Only indirectly programmable from the PLC (
ASUB
).
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...