Description of formal parameters
The table below lists all formal parameters of the GETGUD function.
Signal
Typ
e
Type
Range of values
Remark
Req
I
BOOL
Job start with positive signal edge
Addr
I
ANY
[DBName].[VarName]
GUD variable name in a variable of
data type STRING
Area
I
BYTE
Area address:
0: NCK variables
2: Channel variables
Unit
I
BYTE
NCK area: Unit:=1
Channel area: Channel no.
Index1
I
INT
Field index 1 of variable
Variable has the value 0 if no field
index is used.
Index2
I
INT
Field index 2 of variable
Variable has the value 0 if no field
index is used.
CnvtToken
I
BOOL
Activate generation of a variable
token
VarToken
I
ANY
[DBName].[VarName]
Address to a 10byte token (see
example)
Error
Q
BOOL
Negative acknowledgment of job or
execution of job impossible
Done
A BOOL
Job successfully executed
State
A WORD
See error identifiers
RD
I/O ANY
P#Mm.n BYTE x...
P#DBnr.dbxm.n BYTE x
Data to be written
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...