Detailed description
2.12 Block descriptions
Basic logic functions: PLC Basic program powerline (P3 pl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
151
Declaration of the function
FUNCTION_BLOCK FB 5
//Server name
KNOW_HOW_PROTECT
VERSION : 3.0
VAR_INPUT
Req :
BOOL ;
Addr:
ANY ;
//Variables name string
Area:
BYTE ;
//Area: NCK = 0, channel = 2
Unit :
BYTE ;
Index1:
INT ;
//Field index 1
Index2:
INT ;
//Field index 2
CnvtToken:
BOOL ;
//Conversion into 10-byte token
VarToken:
ANY ;
//Struct with 10 bytes for the variable token
FMNCNo :
INT ;
//(in FMNC only)
END_VAR
VAR_OUTPUT
Error :
BOOL ;
Done :
BOOL ;
State :
WORD ;
END_VAR
VAR_IN_OUT
RD:
ANY ;
END_VAR
BEGIN
END_FUNCTION_BLOCK
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...