Detailed Description
2.3 Configurable gear adaptation
Basic logic functions: Spindles (S1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
55
End of oscillation mode
On termination of oscillation mode, the spindle returns to openloop control mode and
automatically changes to the mode defined by
SPCON
or
SPCOF
.
All gearspecific limit values (min./max. speed, etc.) correspond to the set values of the actual
gear step.
Functionality
Machine tools of conventional design require a gear step change of the spindle in oscillation
mode.
If the machine data configuration is:
MD35010 $MA_GEAR_STEP_CHANGE_ENABLE = 1
the following sequence is implemented:
•
Deceleration of the spindle.
The braking action corresponds to an M5 movement.
•
Output of VDI interface signals:
DB31, ... DBX84.6 (Oscillation mode)
DB31, ... DBX82.3 (Change gear)
DB31, ... DBX82.0-82.2 (Set gear step A to C).
If position control has been enabled, it is disabled:
DB31, ... DBX61.5 = 0.
•
The load gearbox can now "disengage".
•
NC/PLC IS:
DB31, ... DBX18.5 (Oscillation enable)
can be set by the PLC.
The spindle motor then performs an oscillation motion with preset values.
The oscillation motion is designed to facilitate and accelerate the reengaging of the gear
wheels.
•
Writing of NC/PLC IS:
DB31, ... DBX16.0-16.2 (Actual gear step A to C)
by the PLC.
•
Once the PLC has sent:
DB31, ... DBX16.3 (Gear changed)
to the NCK, the last movement to be active is continued, if available.
For indirect encoders (motor encoders), the homing status is cleared:
DB31, ... DBX60.4/5 = 0.
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...