Detailed description
2.9 Program control
Basic logic functions: Mode group, channel, program operation, reset response (K1)
148
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
2.9.1
Function selection (via operator panel front or PLC)
Operator interface or PLC
The user can control part program execution via the operator panel front or PLC.
Selection, activation, feedback
Selection
Different functions are available under the Program control soft key. Selection affects an
interface signal in the PLC. These signals are to be understood as selection signals from the
operator interface, and do not activate the selected function.
Activation
These signal states must be transferred to another area of the data block to activate the
selected function. With program control by the PLC the signals are to be set directly.
Feedback
The activated functions are partly signaled back to the PLC from the NCK.
Table 2-11 Program control: Interface signals
Function
Selection signal
Activation signal
Feedback signal
SKP skip block 0 to 7
SKP skip block 8 to 9
DB21, ... DBX26.0 - 26.7
DB21, ... DBX27.0 - 27.1
DB21, ... DBX2.0 - 2.7
DB21, ... DBX31.6 - 31.7
- - -
DRY dry run feedrate
DB21, ... DBX24.6
DB21, ... DBX0.6
DB21, ... DBX318.6
ROV Rapid traverse override
DB21, ... DBX25.3
DB21, ... DBX6.6
- - -
Single block:
Preselection of SBL1, SBL2 or SBL3 via program control display of HMI
SBL1: Action single block
SBL2: Decoding single block
SBL3: In cycle
HMI operator panel
DB21, ... DBX0.4
- - -
M01 (Programmed stop)
DB21, ... DBX24.5
DB21, ... DBX0.5
DB21, ... DBX32.5
Associated M01
DB21, ... DBX24.4
DB21, ... DBX30.5
DB21, ... DBX318.5
DRF selection
DB21, ... DBX24.3
DB21, ... DBX0.3
DB21, ... DBX33.3
PRT program test
DB21, ... DBX25.7
DB21, ... DBX1.7
DB21, ... DBX33.7
References:
/FB1/Function Manual Basic Functions; NC/PLC Interface Signals (Z1)
/BAD/ Operation Manual HMI Advanced "Operating Area, Machine"
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...