Detailed Description
2.1 Various interface signals and functions (A2)
Basic logic functions: NC/PLC interface signals (Z1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
45
DB31, ...
DBX61.5
Position controller active
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change
0 → 1
The control signals that the position controller for the axis or spindle is closed.
Signal state 0 or
edge change
1 → 0
The control signals that the position controller for the axis or spindle is open.
If "controller enable" is canceled because of a fault or from the PLC user program the position
controller is opened and therefore the interface signal
DB31, ... DBX61.5 (position controller active)
is set to 0.
Spindle without position control: Signal "Position controller active" is always "0".
See References for other effects.
Application
example(s)
If the position control is active the axis/spindle is kept in position by the position controller.
Any brakes or clamps can thus be opened.
The interface signal:
DB31, ... DBX61.5 (position controller active)
can be used as feedback signal for the interface signal:
DB31, ... DBX2.1 (controller enable).
The holding brake of a vertical axis must be activated as soon as the position control is no longer
active.
If a spindle has been technically designed/dimensioned for the purpose, in the part program, it can
be changed-over into the closed-loop position controlled mode as spindle or as axis (with
SPCON
or
M70
).
In these cases, the interface signal "position controller active" is set.
Special cases,
errors, ....
Special case for simulation axes (MD30350 $MA_SIMU_AX_VDI_OUTPUT = "1"):
The IS "position controller active" is also set for simulation axes as soon as MD = "1".
Corresponding to .... DB31, ... DBX2.1 (controller enable)
DB31, ... DBX1.4 (follow-up mode)
DB31, ... DBX1.5 and 1.6 (position measuring system 1 and 2)
Additional references /DA/ Diagnostics Guide
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...