Detailed description
2.11 Response to overstore
Basic logic functions: Auxiliary Function Output to PLC (H2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
45
2.11
Response to overstore
Overstore
Before the start, on the SINUMERIK operator interface, the following functions:
•
NC START of a part program
•
NC START to resume an interrupted part program
the auxiliary functions that are output at the start can be changed by the "Overstore"
function.
Possible applications include:
•
Addition of auxiliary functions after block search
•
Restoring the initial state to position a part program
Types of auxiliary functions that can be overstored
The following types of auxiliary functions can be overstored:
•
M (special function)
•
S (spindle speed)
•
T (tool number)
•
H (aux. function)
•
D (tool offset number)
•
DL (additive tool offset)
•
F (feed)
Duration of validity
An overstored auxiliary function, e.g.
M3
(spindle right), is valid until it is overwritten by
another auxiliary function from the same auxiliary function group, by additional overstoring or
by programming in a part program block.
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...