Data lists
5.1 Machine data
Basic logic functions: Reference Point Approach (R1)
60
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Number
Identifier: $MA_
Description
31123
BERO_DELAY_TIME_MINUS
BERO delay time in minus direction
34000
REFP_CAM_IS_ACTIVE
Axis with reference cam
34010
REFP_CAM_DIR_IS_MINUS
Reference point approach in minus direction
34020
REFP_VELO_SEARCH_CAM
Homing approach velocity
34030
REFP_MAX_CAM_DIST
Maximum distance to reference cam
34040
REFP_VELO_SEARCH_MARKER
Reference point creep velocity
34050
REFP_SEARCH_MARKER_REVERSE
Direction reversal to reference cam
34060
REFP_MAX_MARKER_DIST
Maximum distance to reference mark;
Max. distance to 2 reference mark for distance-coded
scales
34070
REFP_VELO_POS
Reference point positioning velocity
34080
REFP_MOVE_DIST
Reference point distance/destination point for
distancecoded system
34090
REFP_MOVE_DIST_CORR
Reference point/absolute offset, distancecoded
34092
REFP_CAM_SHIFT
Electronic reference cam shift for incremental
measurement systems with equidistant zero marks.
34093
REFP_CAM_MARKER_DIST
Reference cam/reference mark distance
34100
REFP_SET_POS
Reference point value
34102
REFP_SYNC_ENCS
Actual value adjustment to the referencing
measurement system
34104
REFP_PERMITTED_IN_FOLLOWUP
Enable referencing in followup mode
34110
REFP_CYCLE_NR
Axis sequence for channelspecific Homing
34120
REFP_BERO_LOW_ACTIVE
Polarity change of the BERO cam
34200
ENC_REFP_MODE
Referencing mode
34210
ENC_REFP_STATE
Status of absolute encoder
34220
ENC_ABS_TURNS_MODULO
Absolute encoder range for rotary encoders
34230
ENC_SERIAL_NUMBER
Encoder serial number
34232
EVERY_ENC_SERIAL_NUMBER
Expansion of encoder serial number
34300
ENC_REFP_MARKER_DIST
Basic distance of reference marks for distance-coded
encoders
34310
ENC_MARKER_INC
Interval between two reference marks with distance-
coded scales
34320
ENC_INVERS
Linear measuring system inverse to machine system:
34330
REFP_STOP_AT_ABS_MARKER
Distancecoded linear measuring system without
destination point
35150
SPIND_DES_VELO_TOL
Spindle speed tolerance
36302
ENC_FREQ_LIMIT_LOW
Encoder limit frequency resynchronization
36310
ENC_ZERO_MONITORING
Zero mark monitoring
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...