Parameter list
05.05
11-134
SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U369
(2369)
*
S00
(B206)
Source for input signals, OR element 20
(output = B9399)
FB
169
As for U350
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
EXCLUSIVE OR elements with 2 inputs each
The input signals selected via the 2 indices of the parameter are combined in an EXCLUSIVE OR (XOR) operation and the result applied
to the specified binector..
U370
(2370)
*
S00
(B206)
Source for input signals, XOR element 1
(output = B9195)
FB
170
i001
Source for input 1
i002
Source for input 2
Settings:
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U371
(2371)
*
S00
(B206)
Source for input signals, XOR element 2
(output = B9196)
FB
171
As for U370
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U372
(2372)
*
S00
(B206)
Source for input signals, XOR element 3
(output = B9197)
FB
172
As for U370
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U373
(2373)
*
S00
(B206)
Source for input signals, XOR element 4
(output = B9198)
FB
173
As for U370
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Inverters
The input signal is inverted and the result applied to the specified binector.
U380
(2380)
*
S00
(B207)
Source for input signal, inverter 1
(output = B9450)
FB
180
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U381
(2381)
*
S00
(B207)
Source for input signal, inverter 2
(output = B9451)
FB
181
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U382
(2382)
*
S00
(B207)
Source for input signal, inverter 3
(output = B9452)
FB
182
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U383
(2383)
*
S00
(B207)
Source for input signal, inverter 4
(output = B9453)
FB
183
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U384
(2384)
*
S00
(B207)
Source for input signal, inverter 5
(output = B9454)
FB
184
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U385
(2385)
*
S00
(B207)
Source for input signal, inverter 6
(output = B9455)
FB
185
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U386
(2386)
*
S00
(B207)
Source for input signal, inverter 7
(output = B9456)
FB
186
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......