05.05
Parameter list
SIEMENS AG 6RX1700-0AD76
11-165
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
11.86 Configuring the EB1 expansion board
U755
(2755)
*
(Z112)
(Z115)
Signal type of analog inputs on EB1
[SW 1.5 and later]
0 = Voltage input 0 to
±
10 V
1 = Current input 0 to
±
20 mA
i001: AI1 of the first EB1
i002: AI1 of the second EB1
0 to 1
1
Ind: 2
WE=0
Typ: O2
P052 = 3
P051 = 40
on-line
U756
(2756)
(Z112)
(Z115)
Normalization of analog inputs on EB1
[SW 1.5 and later]
This parameter specifies the percentage value which is generated for an
input voltage of 10V (or an input current of 20mA) at the analog input.
The following general rule applies:
With a voltage input:
U
V
Y
X
756
10
[%]
=
∗
X .. input voltage in volts
Y .. % value which is generated for input
voltage
X
With a current input:
U
mA
Y
X
756
20
[%]
=
∗
X .. input current in mA
Y .. % value which is generated for input
current X
i001: AI1 of the first EB1
i002: AI2 of the first EB1
i003: AI3 of the first EB1
i004: AI1 of the second EB1
i005: AI2 of the second EB1
i006: AI3 of the second EB1
-1000.0 to 1000.0
[%]
0.1%
Ind: 6
WE=100,0
Typ: I2
P052 = 3
P051 = 40
on-line
U757
(2757)
(Z112)
(Z115)
Offset for analog inputs on EB1
[SW 1.5 and later]
i001: AI1 of the first EB1
i002: AI2 of the first EB1
i003: AI3 of the first EB1
i004: AI1 of the second EB1
i005: AI2 of the second EB1
i006: AI3 of the second EB1
-100.00 to 100.00
[%]
0.01%
Ind: 6
WE=0,00
Typ: I2
P052 = 3
P051 = 40
on-line
U758
(2758)
*
(Z112)
(Z115)
Mode of signal injection at analog inputs on EB1
[SW 1.5 and later]
0 = Injection of signal with sign
1 = Injection of absolute value of signal
2 = Injection of signal with sign, inverted
3 = Injection of absolute value of signal, inverted
i001: AI1 of the first EB1
i002: AI2 of the first EB1
i003: AI3 of the first EB1
i004: AI1 of the second EB1
i005: AI2 of the second EB1
i006: AI3 of the second EB1
0 to 3
1
Ind: 6
WE=0
Typ: O2
P052 = 3
P051 = 40
off-line
U759
(2759)
*
(Z112)
(Z115)
Source for selection of sign reversal at
[SW 1.5 and later]
analog inputs on EB1
Selection of binector to control
sign reversal at the analog input
("1" state
= reverse sign)
0 = binector B0000
1 = binector B0001
etc.
i001: AI1 of the first EB1
i002: AI2 of the first EB1
i003: AI3 of the first EB1
i004: AI1 of the second EB1
i005: AI2 of the second EB1
i006: AI3 of the second EB1
All binector numbers
1
Ind: 6
WE=0
Typ: L2
P052 = 3
P051 = 40
off-line
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......